Location:PRODUCTS >> Hydraulic control valve >> Electric control valve
Electric control valve
Model: 600X
Nominal diameter: DN40 ~ 1600mm
Nominal: PN1.0 ~ 2.5MPa
Suitable medium: water, oil, water, sewage
Temperature: 0 ~ 80 ℃
Structure length standard: GB / T12221-2005
Connection flange Standard: GB / T9113
Pressure Temperature Level: GB / T12224-2005
Test Standards: GB / T13927-2008

600X electric control valve is a solenoid valve for the pilot valve hydraulic valve. Commonly used in water supply and drainage and industrial systems in the automatic control, accurate and rapid response control, remote control according to the electrical signal to open and close the pipeline system for remote operation.

 
600X electric control valve and can replace the gate valve and butterfly valve for large electric operating system. Valve closing speed adjustable, closed without pressure fluctuations. The valve is small, light weight, easy maintenance, easy to use, safe and reliable. Solenoid valve optional AC 220V, or DC 24V, according to various occasions, the use of normally open or normally closed can be
 

600X electric control valve structure features and uses

600X electric control valve consists of main valve, solenoid pilot valve, needle valve, ball valve, microfilter and pressure gauge to form a hydraulic control takeover system. Through the solenoid pilot valve can be opened and closed on the remote control valve. After installing additional devices, you can control the speed of opening and closing. Electrically controlled hydraulic control valve using the pilot valve to open and close the valve to save energy. Can replace other valves large electric devices. Electrically controlled hydraulic control valve products are widely used in high-rise buildings, living areas and other water supply pipe network systems and urban water supply projects.
 

600X electric control valve works

When the valve from the inlet end of the water, the water flow through the needle valve into the main valve control room, when the solenoid valve is open, the control room of water through the solenoid pilot valve, ball valve out. Ball valve opening is greater than the needle valve opening, the main valve control chamber pressure is very low, the main valve is fully open state.

When the solenoid valve is closed, the main valve control room of the water can not flow out of the control room to boost the diaphragm to close the main valve.
 

600X electric control valve main technical parameters

Nominal pressure (Mpa)

Shell test pressure (MPa)

Seal test pressure (MPa)

The maximum inlet pressure (MPa)

Export adjustable pressure (MPa)

Suitable media

Medium temperature (℃)

1.0

1.5

1.1

1.0

0.09-0.8

Water

0-80

1.6

2.4

1.76

1.6

0.10-1.2

2.5

3.75

2.75

2.5

0.15-1.6


 600X electric control valve main parts materials

Part Name

Parts and materials

Body valve cover

WCB

Valve seat disc

Copper alloy

O-ring seals

Nitrile rubber

Valve stem

2Cr13

Spring

50CrVA

Needle valve

Copper alloy

Ball valve

Copper alloy

Solenoid pilot valve

stainless steel

Micro filter

stainless steel


Connection Size (PN 1.0-2.5MPa) 

Nominal diameter DN L H H1 A B
50 250 335 90 170 170
65 280 345 98 180 180
80 310 355 110 190 190
100 350 365 120 200 200
125 400 445 145 215 215
150 450 460 155 230 230
200 550 505 190 255 255
250 650 550 250 295 295
300 800 710 290 325 325
350 900 725 330 380 380
400 1000 760 360 415 415
450 1000 810 445 435 435
500 1100 865 495 460 460
600 1100 935 550 520 520
700 1450 1000 605 570 570
800 1560 1100 730 620 620
900 1800 1205 800 670 670
1000 2000 1330 910 830 830


+86-21-69755272
qrCode